Q.01
Can I open with an existing device?
Yes, if it is the right size and in good condition. Get it measured and camera the line before you sign the lease.

Phoenix guide · 3 min read
You have a question about a grease trap in your Phoenix kitchen. The answer is below. When you want a pump-out, ask for a call back.
The grease device is one of the few pieces of kitchen equipment that is designed by code and paid for twice if it is wrong. An undersized interceptor passes plan check, gets installed, and then fails in practice because the kitchen hits the 25 percent limit long before the city calendar. The fix is a new tank, a new permit and a new inspection.
01 / Good to know
The plumbing code and the local pretreatment program decide the minimum, and an engineer or a plumber does the calculation. The inputs are the fixture count, the fixture types, the menu and the hours. A three-compartment sink, a prep sink, a mop sink, a hand sink and a dishwasher are the usual list, and the dishwasher is the fixture that changes the answer.
Tempe's program gives a simple version that is useful anywhere in the Valley: 4 or fewer kitchen fixtures on the grease line can use a hydromechanical trap, and more than 4 fixtures, or any commercial dishwasher, needs a gravity interceptor.

02 / New kitchens
A new device or a replacement is plumbing work. It needs a permit from the city, and the inspection happens before the device is covered. In Phoenix, gravity interceptors go through the plans process, and the city publishes an approved interceptor list.
The permit package usually includes the plumbing plans, the fixture schedule, the device specification and the location. A device that is specified at 500 gallons when the calculation calls for 1,500 is a plan check comment, and a comment is cheaper than a re-installation. An existing device with a missing baffle is a grease trap repair job instead.
03 / Compare
| Concept | Typical device | Why |
|---|---|---|
| Coffee shop, no dishwasher | Small trap | Few fixtures, low fat load |
| Cafe with a dishwasher | Interceptor | Dishwasher trigger |
| Full-service restaurant | Interceptor, 1,000 gallons or more | Fixture count and menu |
| Bar with a food menu | Trap or interceptor | Fryer load decides |
| Food truck commissary | Interceptor or trap per the city | Wash water has to go to a device |
| Bakery | Trap or interceptor | Fat load from pastry and wash |
The table is a starting point, not a design. The fixture count and the menu decide.
04 / Good to know
Those 6 items take an afternoon and they prevent a common first-year problem, which is a device that was pumped but cannot be proven.

05 / New kitchens
The minimum is a floor for a hypothetical kitchen. A real menu with a fryer and a dishwasher usually needs more.
A food truck that washes utensils needs a commissary, and the commissary needs a device. Mesa's requirements state it directly.
Some leases put the device on the tenant. Read the clause before signing, and if it is unclear, get it in writing.
06 / Good to know
If the space was a restaurant before, ask for the device size, the last 12 months of manifests and the name of the service company. If the space was not a restaurant, assume the device is new or absent and budget for one. The answer can change the build-out cost by thousands.
08 / 4 questions
Still have a question?
Send the form with a short note. Someone from our team will call you back soon.
Get a call backQ.01
Yes, if it is the right size and in good condition. Get it measured and camera the line before you sign the lease.
Q.02
The tenant or the landlord, depending on the lease. A new build usually includes it in the tenant improvement.
Q.03
That depends on the city and the completeness of the plans. A device that is specified correctly moves faster.
Q.04
Only if the device cannot meet the standard interval. A correctly sized device does not need one.

Form open 24/7
Ask for a call back about your grease trap
Tell us which device and which kitchen. We will call you back shortly.
Thank you. You will be called back soon.